Modbus MCP Server
About
An MCP server that standardizes and contextualizes industrial Modbus data.
Details
- Author
- kukapay
- GitHub stars
- 25
- Downloads
- 250
- Categories
- Other
Jump to
- Read/write holding registers and coils.
- Read input registers and multiple holding registers.
- Customizable prompt (analyze_register) for register analysis.
- Supports Modbus over TCP, UDP, or serial.
- Configuration via environment variables.
Setting up with Highlight
This MCP is not yet compatible with Highlight’s one-click setup. However, you can still use it with Highlight by following these steps:
- Download and install Highlight from highlightai.com/download
- Navigate to the plugins tab and select "Add Custom Plugin"
-
Configure the plugin with the settings below
Plugin Name
Modbus MCP ServerCommand (node, npx, python, etc.)Please refer to the README for specific instructions on how to obtain API keys or other required environment variables.
- Enable "Start Automatically" if you want the plugin to start when Highlight launches
From the repository
Install Python 3.10 and uv, then clone the repository and run uv sync. Configure connection parameters via environment variables (e.g., MODBUS_TYPE, MODBUS_HOST, MODBUS_PORT) in a .env file or shell. Add the server to Claude Desktop using the provided JSON configuration. Use natural language prompts (client-dependent) or structured JSON (e.g., with MCP Inspector) to invoke tools like read_register, write_register, read_coils, etc.
Claude Desktop / Cursor
Paste into your MCP client config file to install this server.
{
"mcpServers": {
"modbus mcp server": {
"modbus-mcp": {
"command": "uv",
"args": [
"sync"
]
}
}
}
}
McpServers
{
"modbus-mcp": {
"command": "uv",
"args": [
"sync"
]
}
}
Modbus MCP Server
An MCP server that standardizes and contextualizes Modbus data, enabling seamless integration of AI agents with industrial IoT systems.
Features
- Modbus Tools:
- Read/write holding registers (read_register, write_register).
- Read/write coils (read_coils, write_coil).
- Read input registers (read_input_registers).
- Read multiple holding registers (read_multiple_holding_registers).
- Prompt: Analyze Modbus register values with a customizable prompt (analyze_register).
- Flexible Connections: Supports Modbus over TCP, UDP, or serial, configured via environment variables.
Requirements
- Python: 3.10
- uv for dependency and virtual environment management.
Installation
1. Install uv:
curl -LsSf https://astral.sh/uv/install.sh | sh
2. Clone the Repository:
git clone https://github.com/kukapay/modbus-mcp.git
cd modbus-mcp
3. Install Dependencies:
uv sync
Configuration
The server connects to a Modbus device using parameters specified via environment variables. Set these variables in a .env file or your shell environment.
Environment Variables
| Variable | Description | Default | Required |
|------------------------- |--------------------------------------------------|----------------------|----------|
| MODBUS_TYPE | Connection type: tcp, udp, or serial | tcp | Yes |
| MODBUS_HOST | Host address for TCP/UDP | 127.0.0.1 | For TCP/UDP |
| MODBUS_PORT | Port for TCP/UDP | 502 | For TCP/UDP |
| MODBUS_DEFAULT_SLAVE_ID | Slave ID | 1 | For TCP/UDP |
| MODBUS_SERIAL_PORT | Serial port (e.g., /dev/ttyUSB0, COM1) | /dev/ttyUSB0 | For serial |
| MODBUS_BAUDRATE | Serial baud rate | 9600 | For serial |
| MODBUS_PARITY | Serial parity: N (none), E (even), O (odd) | N | For serial |
| MODBUS_STOPBITS | Serial stop bits | 1 | For serial |
| MODBUS_BYTESIZE | Serial byte size | 8 | For serial |
| MODBUS_TIMEOUT | Serial timeout (seconds) | 1 | For serial |
Example .env File
For TCP:
MODBUS_TYPE=tcp
MODBUS_HOST=192.168.1.100
MODBUS_PORT=502
MODBUS_SLAVE_ID=1
For Serial:
MODBUS_TYPE=serial
MODBUS_SERIAL_PORT=/dev/ttyUSB0
MODBUS_BAUDRATE=9600
MODBUS_PARITY=N
MODBUS_STOPBITS=1
MODBUS_BYTESIZE=8
MODBUS_TIMEOUT=1
Usage
Installing for Claude Desktop
The configuration file:
{
"mcpServers": {
"Modbus MCP Server": {
"command": "uv",
"args": [ "--directory", "/path/to/modbus-mcp", "run", "modbus-mcp" ],
"env": { "MODBUS_TYPE": "tcp", "MODBUS_HOST": "127.0.0.1", "MODBUS_PORT": 502 },
}
}
}
Using Tools
Note: Natural language support depends on the client’s ability to parse and map prompts to tools. The MCP Inspector requires structured JSON, but the examples below show how conversational inputs translate.
1. Read a Holding Register:
- Prompt:
Please read the value of Modbus holding register 0.
- MCP Inspector JSON:
{
"tool": "read_register",
"parameters": {"address": 0, "slave_id": 1}
}
- Expected Output:
Value: <register_value>
2. Write to a Holding Register:
- Prompt:
Set Modbus holding register 10 to the value 100.
- MCP Inspector JSON:
{
"tool": "write_register",
"parameters": {"address": 10, "value": 100, "slave_id": 1}
}
- Expected Output:
Successfully wrote 100 to register 10
3. Read Coils:
- Prompt:
Check the status of the first 5 Modbus coils starting at address 0.
- MCP Inspector JSON:
{
"tool": "read_coils",
"parameters": {"address": 0, "count": 5, "slave_id": 1}
}
- Expected Output:
Coils 0 to 4: [False, False, False, False, False]
4. Write to a Coil:
- Prompt:
Turn on Modbus coil 5.
- MCP Inspector JSON:
{
"tool": "write_coil",
"parameters": {"address": 5, "value": true, "slave_id": 1}
}
- Expected Output:
Successfully wrote True to coil 5
5. Read Input Registers:
- Prompt:
Read the values of 3 Modbus input registers starting from address 2.
- MCP Inspector JSON:
{
"tool": "read_input_registers",
"parameters": {"address": 2, "count": 3, "slave_id": 1}
}
- Expected Output:
Input Registers 2 to 4: [<value1>, <value2>, <value3>]
6. Read Multiple Holding Registers:
- Prompt:
Get the values of Modbus holding registers 0 through 2.
- MCP Inspector JSON:
{
"tool": "read_multiple_holding_registers",
"parameters": {"address": 0, "count": 3, "slave_id": 1}
}
- Expected Output:
Holding Registers 0 to 2: [<value1>, <value2>, <value3>]
License
This project is licensed under the MIT License. See LICENSE for details.